Commit Graph
87751 Commits
Author SHA1 Message Date
Eric Kohl 245bc3f44a [NETSH] Simplify the code by naming the root context 'netsh'
-
2025-09-14 22:14:21 +02:00
Hermès Bélusca-Maïto 20d7fd78ae [CMBATT] Fix "TripPpoint" typo 2025-09-13 21:34:18 +02:00
Hermès Bélusca-Maïto 13dc901d8c [KERNEL32][SVCHOST] LoadLibraryEx 2nd parameter is a handle, so, 0 -> NULL 2025-09-13 21:34:10 +02:00
Timo Kreuzer 571ac5e608 [NTOS:PO] Implement SystemBatteryState in NtPowerInformation
This should get us proper battery status display.
2025-09-13 11:38:38 +03:00
Timo Kreuzer 3a6e0d4b65 [BATTC] Fix IOCTL_BATTERY_QUERY_STATUS
Previously the function waited for the conditions *after* querying the status, and then returned the old status. Also, if querying failed, it waited and when the wait timed out it returned STATUS_SUCCESS without returning any data. If the call to SetStatusNotify failed and there was no timeout, it would wait forever.
This is all fixed now.
2025-09-13 11:38:38 +03:00
Eric Kohl ae23b4dc8f [NETSH] Add the PreprocessCommand stub 2025-09-13 09:53:46 +02:00
Hermès Bélusca-Maïto e92be1ede2 [MSGINA] Simplify GetRegistrySettings() (#8381) 2025-09-12 13:53:58 +02:00
Hermès Bélusca-Maïto 27db7ece88 [MSGINA] ReadRegDwordValue(): Support interpreting REG_SZ values as DWORDs when possible (#8381)
This is useful for numerical values that are documented as being stored
in string format as `REG_SZ` in the registry; the reason being that they
are still read or written via `GetProfileIntW()`/`WriteProfileStringW()`
by Windows' Winlogon, and these functions store `REG_SZ` values because
of the INI <-> Registry mapping mechanism.
2025-09-11 16:31:47 +02:00
Timo Kreuzer 01872b8495 [NPFS] Fix dereference of uninitialized variable
- Avoid uninitialized return variables
- Fix a parameter check
2025-09-11 12:31:14 +03:00
Timo Kreuzer 0b18dfe924 [WINETESTS] Move definition of __ROS_LONG64__ to individual tests
This is more explicit than defining it for all wine tests and it directly shows us which tests need to be synced to get rid of the hack.

Addendum to 381e224 (PR #7576)
2025-09-11 09:17:13 +03:00
Timo Kreuzer 570354e984 [ROSTESTS] Remove definitions of __ROS_LONG64__ in testlist.c 2025-09-11 09:17:13 +03:00
Timo Kreuzer 5a8c36d9a1 [SDK] Remove header definitions of __ROS_LONG64__
These were totally pointless, because the condition was never true.
2025-09-11 09:17:13 +03:00
Timo Kreuzer fff6d96000 [WIN32K:NTGDI] Check for failure of PATH_CreatePath
Also use common cleanup path.
2025-09-10 16:39:22 +03:00
Timo Kreuzer 8a2a587e57 [WIN32K:NTGDI] Save and restore FP state in IntGdiWidenPath 2025-09-10 16:39:22 +03:00
Whindmar Saksit 3d70478560 [SHELL32] Implement the RunAs dialog and verb (#5787)
Implements the "run as another user" part.
2025-09-10 15:21:04 +02:00
Whindmar Saksit 69df57245c [SHELL32] Fix CompareIDs DISK_CAPACITY (#8376)
Addendum to PR #8361

CORE-20286
2025-09-09 17:52:40 +02:00
Eric Kohl 0793006523 [IFMON] Add first netsh helper dll
Run 'add helper ifmon.dll' in netsh to load the ifmon helper.
2025-09-08 02:00:34 +02:00
Eric Kohl df01941faf [NETSH] Fix helper and context issues 2025-09-08 01:55:04 +02:00
Eric Kohl 1c1b8a2260 [NETSH] Print proper prompt 2025-09-08 01:11:22 +02:00
Doug Lyons 5d5e5d1a46 [NTGDI] Fix SAI Paint Tool Initial Graphics Display (#8348)
CORE-15002
2025-09-06 19:20:44 -05:00
Hermès Bélusca-Maïto 38398fbaf3 [MSGINA] Fix gcc x86 build
Addendum to commit 1499e7ef53.

Poor thing was crying that it was ignoring trigraph `??)`, even
though this whole thing was inside an `#if 0`-commented block...
Use something else instead.

```
msgina/shutdown.c: In function 'ShutdownDialog':
msgina/shutdown.c:1217:56: error: trigraph ??) ignored, use -trigraphs to enable [-Werror=trigraphs]
     pgContext->nShutdownAction = LoadShutdownSelState(???);

msgina/shutdown.c: At top level:
cc1: error: unrecognized command line option '-Wno-unknown-warning-option' [-Werror]
```
2025-09-05 11:55:40 +02:00
Hermès Bélusca-Maïto a1bbcee5e8 [MSCOREE] Show a user popup if .NET is missing (#8374)
Otherwise, you wouldn't see anything at all when opening a .NET app, and
the only hint that a .NET runtime is needed would be to see the message
in the debug log, provided a debugger is connected to ReactOS ...

NOTE: `shell32!ShellMessageBoxA()` is used instead of
`user32!MessageBoxA`, because it turns out mscoree isn't importing
from user32 but from shell32 instead (as in Wine's), and I don't want
to modify the list of imported modules.

NOTE 2: This warning function has been gradually removed with Wine commits:
  https://github.com/wine-mirror/wine/commit/c99754ef15a8e5bc0fd9189fc81e4e4d9cc1f589
  https://github.com/wine-mirror/wine/commit/6b889fe9188a97765bcbcc2cae5ca2480a73e7af
  https://github.com/wine-mirror/wine/commit/5cd6db03495d73e3db024472514a753a44a06772
  https://github.com/wine-mirror/wine/commit/26c9bd9f15c364215be9731bb050454c14d90767
Now, a mere `ERR("Wine Mono is not installed\n");` is emitted.
2025-09-04 23:02:20 +02:00
Hermès Bélusca-Maïto 9d3809febd [BOOTDATA] Disable logoff/password-change/workstation-lock in the LiveCD (#8373)
- Disable "Log Off" from the Start Menu and the C-A-D Security dialog;

- Disable the "Lock Workstation" and "Change Password" buttons in the
  Security dialog.

These are only "UI"-usability features to prevent the user from
logging off when running the LiveCD. (Logging off from the SYSTEM
account, and changing its password, don't make much sense.)

CORE-11397
2025-09-04 22:58:48 +02:00
Hermès Bélusca-Maïto 1499e7ef53 [MSGINA] Improve Security and Shutdown dialog features (#8372)
- Respect system policies for showing or hiding:

  * Security dialog "Lock Workstation", "Log Off", "Shut Down",
    "Change Password", "Task Manager" buttons;

  * "Log Off" entry in the Shutdown dialog;

- Disable the "Shut Down" Security dialog button, and the "Stand by",
  "Shut down" entries in the Shutdown dialog, if the logged user
  doesn't have the SeShutdownPrivilege.

- Add other missing `WLX_SHUTDOWN_STATE_*` shutdown flags that are
  supported by Windows.

- Improve the retrieval of shutdown options to be displayed in the
  "Shut Down" dialog. In particular, don't hardcode any sort of
  defaults, but let them come from what the user can do (Is logoff
  allowed? Does (s)he have the rights to shutdown/reboot? etc.).
  If no shutdown options are available, then simply don't display
  the dialog!

- Don't hardcode the default selected shutdown option. Either it comes
  from the user's registry and is valid (i.e. corresponds to an existing
  shutdown option in the dialog), otherwise, fall back to the first
  option in the dialog.

  In particular this means:
  * when opening the "Shut Down" dialog from the C-A-D Security
    dialog, by default we will select the "Log Off" option, or
    whatever the user last selected;
  * when opening the dialog from the "Turn Off" Start Menu item, default
    to the "Shut down" option, or whatever the user last selected.
  * when opening the dialog from the C-A-D "Log On" dialog (no user
    is logged in), the "Shut down" option will also be selected, or
    whatever the system operator last selected.

- For the shell-invokable `ShellShutdownDialog()` function, implement
  support for using a custom display user name, or the one in the
  `"Logon User Name"` registry value saved by `WlxActivateUserShell()`.
  Plus, the 3rd parameter specifies the list of shutdown options to
  *exclude* from the options list.
2025-09-04 22:57:23 +02:00
Whindmar Saksit 87df3ea3e1 [SHLWAPI][EXPLORER] Implement OS_SERVERADMINUI (#7051)
OS_SERVERADMINUI changes minor things in Explorer, the most visible is that the default folder view mode changes from large icons to details
2025-09-04 19:25:43 +02:00
Mark Jansen db57e02d6b [APPCOMPAT] Add RendererFull3D flag
This flag will be used for DDraw experiments.
CORE-20322
2025-09-04 15:23:48 +02:00
Hermès Bélusca-Maïto 0b43959beb [MSGINA] OnInitSecurityDlg(): Remove unnecessary code (#8371)
The Security dialog can be displayed only when a user is logged.
When this is so, the `pgContext->bAutoAdminLogon` has already been
reset to `FALSE`, see `gui.c!DoLogon()`. Thus there is really no
reason to disable the "Log Off" button in that case.

Addendum to commit c633b79451 (r61622)
2025-09-04 11:55:07 +02:00
Hermès Bélusca-Maïto b306f46e5b [MSGINA] Revisit WlxActivateUserShell(), add support for "Logon User Name" (#8370)
- Add SAL annotations;
- Avoid using hardcoded buffer sizes in function calls.

- If the start-application (Userinit) launched successfully, store
  in the logged-in user's Explorer key, value `"Logon User Name"`,
  the user name that was entered verbatim in the "Log On" dialog
  to log into the system. This value is used as a "convenience" to
  display the `"Log Off <username>"` item in the explorer's Start menu
  (see `explorer!util.cpp:GetCurrentLoggedOnUserName()`), and the
  corresponding item in the "Shut Down" dialog.

- utils.c: Introduce the `RegOpenLoggedOnHKCU()` helper, for opening
  the current logged-in user HKCU key.

  NOTE: Regarding the `.Default` registry key, see:
  https://devblogs.microsoft.com/oldnewthing/20070302-00/?p=27783
2025-09-04 11:47:01 +02:00
Hermès Bélusca-Maïto 55ed59c379 [MSGINA] ReadRegDwordValue(): Return valid errors on data validation (#8370) 2025-09-04 11:47:00 +02:00
Hermès Bélusca-Maïto e7073d2639 [MSGINA] Move some utility functions to a separate utils.c file (#8370)
- Registry-value getters; string copy functions.

- ReadRegSzValue(): Use a meaningful error value
  when the value type isn't the expected one.

- Rename `DuplicationString` -> `DuplicateString`
2025-09-04 11:46:59 +02:00
Hermès Bélusca-Maïto c6fecdda65 [NTUSER] NtUserSetLogonNotifyWindow(): Lock-protect access to global data (#8369)
Like with all the other win32k NtUser* functions, acquire on entry and
release on exit the global lock, since the function is reading/writing
to global variables.

Also, set the last-error to ERROR_ACCESS_DENIED if the caller isn't the
registered logon process.
2025-09-04 11:43:30 +02:00
Hermès Bélusca-Maïto 10d57cb8b2 [NTUSER] IntLanguageToggle(): Guard against NULL pFocusQueue (#8368)
Addendum to commit 25b7447818 (PR #5839)
2025-09-04 11:42:06 +02:00
Hermès Bélusca-Maïto 6a6ed54495 [NTUSER] Some lifting for the Int/UserGet[Active|Capture|Foreground|ThreadFocus]Window() functions 2025-09-04 11:41:57 +02:00
Eric Kohl 999502cfc4 [NETSH] Improve PrintMessageFromModule
Thanks a lot for the hint, Hermès!
2025-09-02 00:31:47 +02:00
Whindmar Saksit 4dc61a2518 [SHELL32] Computer folder sorting must handle mixed drives and regitems (#8361)
CORE-20286
2025-09-01 17:38:36 +02:00
Eric Kohl bb57f63a26 [NETCFGX] Store network interface settings in the correct location 2025-08-31 17:14:41 +02:00
Eric Kohl 2840fdcfe3 [NETCFGX] Handle the interface metric value correctly 2025-08-31 16:45:39 +02:00
Hermès Bélusca-Maïto c1921754aa Revert "[WINLOGON] Temporarily hack around a bug in PSEH for GCC"
This reverts commit ddbe9719c9, now that PSEH has been fixed
in commit d50b8c93fb (PR #8350).

CORE-20307 CORE-20309 CORE-20316
2025-08-30 17:10:07 +02:00
Timo Kreuzer d50b8c93fb [PSEH] Fix a bug with try inside except
PSEH has 2 scopes: an outer scope, that starts with _SEH3_TRY and ends with _SEH3_END, and an inner scope that goes around the try block only. PSEH tracks try-levels by using an enum, which increments at every new TRY scrope, and which needs to be accessible in the outer scope for all registration and cleanup to work. But it should only increment when nested within the inner try scope, not from the except scope. This is fixed by adding an additional _SEH3$_InnerTryLevel, which increments only within the try block, but resets to the parent-value outside of it.

Should fix CORE-20316.
2025-08-30 17:09:02 +03:00
Timo Kreuzer 194be7a2e0 [COMPILER_APITEST] Add another SEH test
See CORE-20316
2025-08-30 17:09:02 +03:00
Mark Jansen 0d11eb1e23 [APPHELP] Add noisy stub for SdbGetDatabaseInformationByName 2025-08-29 21:55:40 +02:00
Hermès Bélusca-Maïto b3a0b4124a [MSGINA] Zero out and don't return old user login info on aborted logon attempts
- WlxLogoff(): Zero out cached Winlogon buffer pointers and some more
  user login info.

- WlxLoggedOutSAS(): Return the logged-in user token handle *ONLY* if
  the user is actually logging into the system.
  If (s)he doesn't log in, but instead cancels the Log-On dialog, or
  chooses to Shutdown/Reboot the computer from that dialog, do *NOT*
  return any previous logged-in user token handle.

  For example, in the case of a previously failed logon attempt due
  to a wrong or corrupted user profile, shutting down the computer
  from the Log-On dialog would show the following errors in the debugger:
  ```
  err:(.../winlogon/sas.c:757) ImpersonateLoggedOnUser() failed with error 6
  err:(.../winlogon/sas.c:859) Shutdown thread returned failure
  err:(.../winlogon/sas.c:1182) Failed to start the Shutdown thread, Status 0xc0000001
  ```
2025-08-29 18:23:55 +02:00
Whindmar Saksit 8ce870d87b [RAPPS] Added /S switch for silent installs (#8241)
MSI, Inno and NSIS installers are automatically detected (also if they are nested by ExeInZip). Others can specify command line switches in the rapps-db package.
2025-08-29 15:18:55 +02:00
Justin Miller 47d6b3ae12 [CMAKE] Globally add -Wno-format (#8352)
We've talked about doing this, We thought about doing this,
we do it for half the modules when we sync them anyway.

Let's just do it.
2025-08-28 13:18:35 -07:00
50d761b492 [SAMSRV] Update Polish (pl-PL) translation (#8195)
* Update pl-PL.rc

* Fix header

* Update dll/win32/samsrv/lang/pl-PL.rc

Co-authored-by: Adam Słaboń <[email protected]>

---------

Co-authored-by: Stanislav Motylkov <[email protected]>
Co-authored-by: Adam Słaboń <[email protected]>
2025-08-27 12:32:15 +02:00
Serge Gautherie c3bb9d6ca9 [UNIATA] UniataChipDetect(): Workaround AHCI detection (#8184)
Fix AHCI support regression.
Disable a "new" code block, which is broken.

Reverts a part of commit 1afae58191 (r69699).
CORE-13346
2025-08-26 22:50:22 +02:00
Hermès Bélusca-Maïto ddbe9719c9 [WINLOGON] Temporarily hack around a bug in PSEH for GCC
Commit 51ee32f5f8 moved the `WNetClearConnections()` in the main
Winlogon thread, where it now runs.

`WNetClearConnections()` calls a 3rd-party module (nfs41_np.dll)
that invokes `kernel32!OutputDebugStringA()`.
The SEH usage pattern in `OutputDebugStringA()`, when compiled with
GCC and PSEH, generates an erroneous chain of exception handlers, that,
when running in an execution environment like that of winlogon.exe,
triggers a crash. See CORE-20316 for more details and testing.

As a temporary measure, hackfix away the problem by surrounding the
`WNetClearConnections()` call in a `_SEH2_TRY/_SEH2_EXCEPT` block
(the net effect is to "add" the missing exception handler entry).

Hack for commit 51ee32f5f8
CORE-20307 CORE-20309 CORE-20316
2025-08-26 22:40:42 +02:00
Justin Miller 6a06b0a05a [ROSTESTS][SHELL32] The shellexec(n) tests are broken on Windows (#8349)
They leave a bunch of processes spawned forever preventing the system from shutting down
2025-08-25 15:11:55 -07:00
Hermès Bélusca-Maïto 320bc52fb4 [NDK][RTL] Use LOGICAL also for RtlIsCriticalSectionLocked(ByThread)
This change has been validated with the System Informer phnt headers.
2025-08-25 23:11:57 +02:00
Hermès Bélusca-Maïto ef5eadafb1 [NDK][RTL] Fix RtlTryEnterCriticalSection() return type
The Win32 TryEnterCriticalSection(), which returns a 32-bit BOOL,
directly redirects to NTDLL!RtlTryEnterCriticalSection().

The latter should therefore return a 32-bit boolean as well:
use the LOGICAL type for this purpose. This change has been
validated with the System Informer phnt headers.

This mismatch was caught by Marcin Jabłoński (TheNNX).
2025-08-25 23:11:56 +02:00