From 5e2fe08918fc5a3c52d586a8dc8b8df851473c20 Mon Sep 17 00:00:00 2001 From: Eric Kohl Date: Wed, 19 Sep 2018 16:35:12 +0200 Subject: [PATCH] [WLNOTIFY] Disable the Logoff-Handler routine for the scheduler service. The Logoff-Handler might try to notify the scheduler service which might already have been shut down. We need to fix the shutdown sequence, so that the service manager stops all running services. Might fix CORE-14521. --- dll/win32/wlnotify/schedsvc.c | 4 ++++ 1 file changed, 4 insertions(+) diff --git a/dll/win32/wlnotify/schedsvc.c b/dll/win32/wlnotify/schedsvc.c index edf89e29ec8..ffca3353863 100644 --- a/dll/win32/wlnotify/schedsvc.c +++ b/dll/win32/wlnotify/schedsvc.c @@ -17,9 +17,11 @@ WINAPI SchedEventLogoff( PWLX_NOTIFICATION_INFO pInfo) { +#if 0 SC_HANDLE hManager = NULL; SC_HANDLE hService = NULL; SERVICE_STATUS ServiceStatus; +#endif TRACE("SchedEventLogoff\n"); TRACE("Size: %lu\n", pInfo->Size); @@ -31,6 +33,7 @@ SchedEventLogoff( TRACE("hDesktop: %p\n", pInfo->hDesktop); TRACE("pStatusCallback: %p\n", pInfo->pStatusCallback); +#if 0 hManager = OpenSCManagerW(NULL, NULL, SC_MANAGER_CONNECT); if (hManager == NULL) { @@ -56,6 +59,7 @@ done: if (hManager != NULL) CloseServiceHandle(hManager); +#endif }